Pt chart 407c

In muscle movement, the synergist is the muscle or group of muscles that stabilizes a joint around which the movement is occurring. The fixator is the muscle or group of muscles that stabilizes the origin of the primary muscle movement and ...

Pt chart 407c. Solutions for Chapter 3 Problem 25RQ: One of the challenges of plotting an R-407C system on a pressure/enthalpy chart is that this refrigerantA. is a single-compound refrigerant with one pressure for each temperature.B. has a significant temperature glide.C. is a binary blend of R-32 and R-125, making it unstable.D. is easily mistaken for R ...

When it comes to understanding Medicaid eligibility, a key tool that can help you determine your eligibility status is the Medicaid eligibility chart. One of the primary factors that determine Medicaid eligibility is income.

R-407C Technical Guidelines R-407C HFC 86.2-43.6 672.1 187 32 72.4 0.289 106.7 0.3597 0.1987 0 1770 A1 10 Applications: Medium temperature commercial and industrial direct expansion refrigeration and A/C Performance: • Slightly lower discharge temperature • Closest capacity match • Similar PT and flow properties = no component changes ...In this HVAC Training Video, I show you How to Read the Refrigerant P/T Chart for the Pressure-Temperature Relationship. This is used to determine the Temper...PT CHART FOR GENETRON® 407C New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the pressure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew” column • Superheat = Actual Temperature -In the following example, R-407C will be used to illustrate the refrigerant total temperature glide, effective temperature glide, fractionation, superheat, subcooling, and average evaporator and condenser temperatures using a refrigerant blend’s pressure/temperature chart. R-407C is a zeotropic refrigerant blend consisting of three HFC ...Additionally, the PT chart also gives you detailed information on the subcool, superheat, and the saturation point of that specific refrigerant. And remember, each refrigerant in the market has a particular PT chart that it uses. ... manufacturers started using different HFC refrigerants to develop blends such as R422B and R407C. HFC …HVAC Shop Talk podcast represents the blue collar boys and girls in the skilled trades, especially HVAC. Listen to HVAC Shop Talk Streaming radio – https://streams ...Forane 408A Pressure Temperature Chart Forane 408A, R-408A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas

R-744 Pressure Chart. ... Instead of pasting a large table of information here I will instead direct you to our specific R-744 refrigerant PT chart. R-744 Applications. Let me first start out by saying that R-744 is a very unique refrigerant, more so then others. R-744 is a natural refrigerant. But, unlike other natural refrigerants, there is not a safety …Freon™ 407C (R-407C) Series Refrigerant Blends Product Information Introduction During the boiling process for a refrigerant, the temperature at which a liquid refrigerant first begins to boil is known as the saturated liquid temperature (also called the bubble point temperature). The temperature at which the last drop AZ-50 (R-507A) Home / Products / Genetron ® AZ-50 (R-507A) Replacement for R-22 or R-502 and is the only azeotrope retrofit option suitable for flooded system conversions. Use for low and medium temperature refrigeration systems. The CO₂e saved by replacing HFCs and HCFCs with Solstice® products throughout 2021 is equivalent to the CO₂ emissions from the energy used by 30.3 million homes, roughly the number of homes in California, Texas, and New York combined.PT CHART FOR GENETRON® 422D New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the press ure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew ” column • Superheat = Actual ...

14 SEER Piston/TXV Reference Chart Information from R410A 14 SEER AC/HP document ©2016 Ingersoll Rand Note: All match ups must be confirmed through AHRI. Condensing Unit Air Handler Piston Size / TXV Valve Model SEER If Preinstalled Piston Replace Required AC M4AC4018B1000AA M4AH4018A100AA MAYTXVACAC1818AA / (049) 14 …The log P/h diagrams on this page can be retrieved from the Coolpack program, which can be downloaded here. This page shows log P/h diagrams for the following refrigerants: R22. R134a. R404A. R407C. …R-404A, R-407C, R-408A, R-409A, R-410A, R-422D, and R-507 are based on vapor free 100°F liquid refrigerant enter-ing the expansion valve, a maximum opening superheat of 7°F, and a standard factory air test superheat setting. A discussion of the relationship between valve capacities and superheat set-tings can be found in Bulletin 10-9. The ratings for …R407c PT Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. 407a pt chart r22 suction pressure temperature chart r22 refrigerant pressure temperature calculator 407c superheat chart how to read a pt chart r407c refrigerant suction pressure discharge pressure r407c refrigerant ideal pressure 407c pt chart and bubble point

Sussy baka face.

PT CHART FOR GENETRON® 407C New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the pressure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew” column • Superheat = Actual Temperature -PT CHART FOR GENETRON® 422D New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the press ure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew ” column • Superheat = Actual ...It is a mixture of R32 (23%), R125 (25%), and R134a (52%) that has a boiling point of -46.84°F. The same as R22, due to useful pressure-temperature properties, R407c is used in air conditioning systems, cars, and refrigeration units. Below, you will find an online R407c PT chart. R407a PT Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. 404a pt chart 407c operating pressures 407f pt chart 407c refrigerant pt chart 407a vs r22 r407a suction and discharge pressure 407a suction pressure r407c refrigerant ideal pressure It is difficult to say exactly how long R-407C will be around. With each year that passes the R-22 machines grow older and older. By the year 2030 there will be very few of them left. Before then though, R-407C will still be needed. Let’s take a look at our pressure chart. R-407C PT Chart

R-407C: Class: HFC: Refrigerant Type: Blend: Typical Lubricant: POE: Notes: Commercial Refrigeration: Reasonable performance match to R-22 in medium temperature refrigeration. Lower capacity in low temperature refrigeration systems. Air Conditioning and Heat Pumps: Best retrofit alternative to R-22. ... [ +] PT Chart Genetron ...Solstice N15 (R-515B) is a nonflammable azeotropic blend designed for chillers, heat pumps and high-ambient air conditioning systems. With a GWP of 293 (4th IPCC), this hydrofluoroolefin (HFO) blend demonstrates environmental and performance benefits in new systems whilst its similar product design to R1234ze provides a long-term solution that is …PT CHART FOR GENETRON® 422D New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the press ure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew ” column • Superheat = Actual ...Make your job easier with our handy refrigerant pressure temperature HVAC app with R-407B included.This product, from the Honeywell Corporation, is an HFC blend made up of R-134a, R-125, and R-32. While it does not have a perfect number when it comes to the Global Warming Potential scale it is significantly reduced when compared to R-404A. While 404A’s GWP is nearly four-thousand the R-407F comes in at only eighteen-hundred. …R-407C Technical Guidelines R-407C HFC 86.2-43.6 672.1 187 32 72.4 0.289 106.7 0.3597 0.1987 0 1770 A1 10 Applications: Medium temperature commercial and industrial direct expansion refrigeration and A/C Performance: • Slightly lower discharge temperature • Closest capacity match • Similar PT and flow properties = no component changes ...Forane 427A Pressure Temperature Chart Forane 427A, R-427A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gasR407C Pressure Temperature Chart 14 8.74 7.73 112.06 7.32 6.31 91.51 16 9.26 8.25 119.63 7.79 6.78 98.33 18 9.81 8.79 127.53 8.29 7.27 105.48

R-407C: Class: HFC: Refrigerant Type: Blend: Typical Lubricant: POE: Notes: Commercial Refrigeration: Reasonable performance match to R-22 in medium temperature refrigeration. Lower capacity in low temperature refrigeration systems. Air Conditioning and Heat Pumps: Best retrofit alternative to R-22. ... [ +] PT Chart Genetron ...

approximately 45°F. Using R-407C, the liquid entering the evaporator may be as cold as 40°F and the vapor temperature before superheat may be 50°F. Some pocket Pressure …R-404A History. R-404A rose to prominence in the late 1990’s with the phasing out of CFC and HCFC refrigerants like R-12 and R-502. There had to be a replacement for the Ozone damaging refrigerants of the past and the successor was the HFC R-404A that we all know of today. 404A’s reign however was short lived.R-407C 32/125/134a (23/25/52) A1 10 POLYOLESTER HFC blend; similar properties to R-22, higher glide. R-410A 32/125 (50/50) A1 0.2 POLYOLESTER HFC blend; higher …Freon™ 407C exhibits performance characteristics similar to R-22. The compositions of Freon™ 407C and Freon™ 407A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 407A (R-407A), wt% 20 40 40 Because Freon™ 407C and Freon™ 407A are mixtures of HFCs, they have zero ozone depletion potential.R407c PT Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. 407a pt chart r22 suction pressure temperature chart r22 refrigerant pressure temperature calculator 407c superheat chart how to read a pt chart r407c refrigerant suction pressure discharge pressure r407c refrigerant ideal pressure 407c pt chart and bubble point R-407C HFC Brown 25 (A), 115 (B), 950 (D), 1,600 (E) R-408A HCFC Medium Purple 20 (A), 24 (A), 100 (B), 1,300 (E) ... Chart mation on one of the leaders in refrigerants and how we can help you, visit forane.com. PRESSURE (PSIG)* PRESSURE (PSIG)* Sat Temp (°F) R-22 R-32 R-123 R-134a R-401A22.4 80.8 190.2 372.5 23.2 82.4 193 377.1 20.9 77.6 184.6 363.5 21.7 79.2 187.4 368 19.4 74.5 179.1 354.6 20.1 76.1 181.8 359 17.9 71.5 173.7 345.9Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253.R-407C HFC Brown 25 (A), 115 (B), 950 (D), 1,600 (E) R-408A HCFC Medium Purple 20 (A), 24 (A), 100 (B), 1,300 (E) ... Chart mation on one of the leaders in refrigerants and how we can help you, visit forane.com. PRESSURE (PSIG)* PRESSURE (PSIG)* Sat Temp (°F) R-22 R-32 R-123 R-134a R-401A

Jesus revolution showtimes near quality 10 powered by emagine.

San jose sale tax.

R-407C 32/125/134a (23/25/52) A1 10 POLYOLESTER HFC blend; similar properties to R-22, higher glide. R-410A 32/125 (50/50) A1 0.2 POLYOLESTER HFC blend; higher pressures, new equipment only. R-422B 125/134a/600a (55/42/3) A1 5 MINERAL OIL or ALKYLBENZENE, POE It can replace R22, R417A and R407C with existing oil in system High Ambient and ...Pressure Temperature Charts Vapor Pressure in PSIG In Vacuum (inches in Hg) °F °C R-407C Liquid R-407C Vapor 60 15.6 118 96.8 65 18.3 129 106 70 21.1 141 117 75 23.9 153 128 80 26.7 166 140 85 29.4 180 153 90 32.2 195 166 95 35.0 210 181 100 37.8 226 196 105 40.6 243 211 110 43.3 261 229 115 46.1 280 247 120 48.9 300 266 125 51.7 321 286 130 54.4 342 307 135 57.2 365 329 140 60.0 389 353Forane 407A Pressure Temperature Chart Forane 407A, R-407A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas*Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R507 (psig)*PT CHART FOR GENETRON® 407C New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the pressure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew” column • Superheat = Actual Temperature -For example, for the refrigerant R-134a, we would look up “R-134a PT Chart”. For the EPA exam, we need to know how to reference PT charts to: Find a saturation pressure given a temperature, or. Find a temperature given a saturation pressure. For refrigerant blends, we will see two pressures in their PT charts: Vapor Pressure, and.Forane 404A Pressure Temperature Chart Forane 404A, R-404A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gasOBTAIN SUCTION PRESSURE 55 PSIG (at bulb) Temperature here reads 26° 20° 6° SUPERHEAT To determine subcooling for R-401A, R-404A, R-407A, R-407F, and R-408A, use BUBBLE POINT (temperatures above 50°F)Similar to other HFC refrigerants, like R-407C or R-404A, the lower amount of superheat included in the evaporator capacity results in a slightly lower relative evaporator capacity for R-438A versus the relative compressor capacity. As expected, the difference decreases as the evaporator temperature increases, with the greatest difference at the lowFreon™ Pressure/Temperature Chart App. The P/T Calculator provides technicians with refrigerant data on the go. Learn More. Sales & Support. Where to Buy; Cylinder Returns ... than R-404A, R-507, and R-407C; A 30% lower GWP vs. R-404A and R-507; Up to 8% improved cooling capacity and up to 14% improved efficiency vs. R-22 at low-temperature ...Hook HVAC gauges to the units high and low refrigerant lines that can read the refrigerant type. The blue gauge goes to the low-pressure side (Big line) and the red to the high-pressure side (Small line). Be sure the HVAC system is running. Check the air temperature at the unit with a thermometer. Look up the correct pressure range on the ...psig t°femperature pdink sean orang light brown reddish purple brown refrigerant - (sporlan code) mp39 or 401a (x) hp80 or 402a (l) hp62 or 404a (s) 407c (n) ….

Temperature (F) R-22 R-410A R-12 R-134a R-404A R-507A R-407A R-407C R-427A R-422B R-422D R-407F R-448A R-421A R-513A R-449A R-452A-48: 4.8: 6: 18: 1.6: 1.3: 1.7: 7.7: 9.8: 10.2free mobile “PT Calculator” app for Apple ® and Android devices that contains P/T conversions and basic product information, as well as allows for easy calculation of subcooling and superheat. Why does the P/T chart for Freon™ MO99 have two columns of data? For any zeotropic blend, there is a saturated liquid R404A PT Chart: Pressure Temperature Chart For -49°F To +150°F; R448a PT Chart: Pressures At -49°F To 150°F Temperatures (+PDF) R407c PT Chart: 407c -49°F To 150°F Pressures (+PDF) R290 PT Chart: Pressures At -44°F To 120°F Temperatures (+PDF) Refrigerant GWP Chart For 61 Freons (R410A, R134A, R22, etc.)R407C Pressure Temperature Chart R407C Temperature (°C) Pressure (barA) Pressure (barg) Pressure (psig) Pressure (barA) Pressure (barg) Pressure (psig)-70 0.24 -0.78 -11.28 0.14 -0.87 -12.63-68 0.27 -0.75 -10.82 0.16 -0.85 -12.32-66 0.30 -0.71 -10.31 0.19 -0.83 -11.97-64 0.34 -0.67 -9.75 0.21 -0.80 -11.59-62 0.38 -0.63 -9.14 0.24 -0.77 -11.15Please select a refrigerant via the drop down menu to display pressure/temperature data.Jan 11, 2020 · R-407C PT Chart Showing 1 to 71 of 71 entries One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicle’s air conditioner is understanding the is 79 psig. The Pressure/Temperature (P/T) chart shows that the saturated vapor temperature, at the dew point, of R-407C for 79 psig is = 51°F. If the actual refrigerant temperature is 60°F the superheat is 9°F. To measure sub-cooling at the condenser outlet or at the TEV inlet to verify that a solid column of liquid is TdX-20-PT-Chart-v1.1 Author: Richard Created Date: 11/23/2015 10:11:01 AM ...Pressure-Temp Chart-40-35-30-25-20-15-10-5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 0.9 3.0 5.4 7.9 10.7 13.8 17.1 20.7 24.7 29.0 33.6 38.6 43.9 49.7 55.9 62.5 69.6 77.2 85.3 94 103 113 123 134 145 158 170 184 198 213 229 246 263 281 301 321 342 Physical Properties of Refrigerants ...PRESSURE TEMPERATURE CHART HIGH ELEVATION 5,000 FEET Red Numerals - Inches Hg. Below 1 ATM Pressure (PSIG) High Elevation 5,000 feet Forane® Cylinder Identification 13/24/25 27/30 lb. (B) 50 lb. (C) 100 110 115/125 145 lb. (D) 100/200 650/690 lb. Drum (E) Container Style: Not to scale Pt chart 407c, Freon™ 407C has excellent refrigerant behavior, even in the event of vapor leaks from a two-phase region of a refrigeration system and subsequent refrigerant recharges. If there is a Freon™ 407C leak from an operating unit in a two-phase region where mixing occurs (heat exchangers or expansion device), both the vapor and liquid will leak from the unit. …, In today’s data-driven world, charts are an essential tool for visually representing information and making it easier to understand. Whether you’re a student, professional, or just someone who loves visualizing data, creating charts has nev..., *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R404A (psig)*, Gantt charts can be versatile tools for project management when used correctly. However, if you’re part of an organization that regularly uses them, you’re also probably aware that they can be confusing if you’re not familiar with how they ..., Part Number. 25 LB. CYLINDER. 100 LB. RETURNABLE CYL. This blend combines HFC and HFO components that produces a lower GWP than traditional HFC products. R-448A is intended for use in low and medium temperature refrigeration systems to replace R-22, R-404A or R-507. It can also be used to retrofit R-22-based blends such as R-402A/B and …, PT Chart Index. Charts use °F and psig. SI Charts are available for SI Boards. Colours show AHRI GUIDELINE N-1995. refrigerant container colour assignment. AHRI is now specifing that all refrigerant containers should. have one uniform paint color, grey RAL 7044 and that the previously assigned colors should be transitioned. , R407c PT Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. 407a pt chart r22 suction pressure temperature chart r22 refrigerant pressure temperature calculator 407c superheat chart how to read a pt chart r407c refrigerant suction pressure discharge pressure r407c refrigerant ideal pressure 407c pt chart and bubble point , Forane ® 407C (R-407C) is a non-ozone depleting, zeotropic blend of HFC refrigerants R-32, R-125, and R-134a, and has been formulated to match the properties of R-22 closely in air conditioning applications. Forane ® 407C can be used to replace R-22 in new or existing R-22 residential and commercial air conditioning systems as well as non ... , PT CHART FOR GENETRON® 422D New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the press ure at the evaporator coil outlet, and a thermometer to get the actual temperature at the same point. • Get the Dew temperature from the “Dew ” column • Superheat = Actual ... , NU-22B® Replaces R-22, R-407C, R-422D and R-417A. Is NU 22 a good home air conditioner replacement for R-22? Freon™ NU-22B™ has an ASHRAE A1 classification and is non-ozone depleting and nonflammable. It is well-suited for AC applications because it closely mimics the operating characteristics of R-22 and works …, R407C, Blend, HFC. Name: R407C: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 81.0 lbs/ft 3: Liquid Density at 80°F , R407C Pressure-Temperature Chart Saturation Pressure-Temperature Data for R407C (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure , As you approach retirement age, it is important to understand how Medicare works and how it affects your retirement plans. One of the most important tools for understanding Medicare is the Medicare Retirement Age Chart., R22 Refrigerant Pressure Temperature Chart. Pressure Temp Chart R-11, R-12, R-22, R123, R134A, R404A, R-500, R502. Using an HVAC refrigerant pressure temperature chart is necessary to be sure a unit is operating correctly. Below are three free pressure temperature charts that can be used to troubleshoot an HVAC unit., When it comes to understanding Medicaid eligibility, a key tool that can help you determine your eligibility status is the Medicaid eligibility chart. One of the primary factors that determine Medicaid eligibility is income., psig t°femperature pdink sean orang light brown reddish purple brown refrigerant - (sporlan code) mp39 or 401a (x) hp80 or 402a (l) hp62 or 404a (s) 407c (n) , Oct 23, 2019 · Learn how to use a pressure-temperature wall chart, pocket chart, or SMART Pro/R app. We will illustrate how pressure and temperature measurements from a ref... , 404R pressure temperature chart is quite simple to understand. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, the pressure of 404A is 456.8 psig. We are, of course, talking about 404A liquid pressure. , R-134A replaced R-12 for automobile air conditioning systems. R-410A is currently being phased in for residential use as the phase period for R-22 draws nearer. The pressure of the refrigerant corresponds with the temperature. Using a PT chart or pressure temperature chart one can determine the pressure or the temperature of the refrigerant., Refrigerants Temperature-Pressure Chart for R-22, R-410A, R-407C, R134A, R404A. Posted on 09/10/2022 11/11/2022 by Leo. Temperature: Refrigerant °F °C: R-22: R-410a: R-407c: R-134a: ... To find the exact value, you should consult the pressure-temperature (PT) chart specific to R404a. We currently have no such data in hand. …, Is R-407C a better refrigerant? R-407C capacity, efficiency, and mass flow rates may be slightly clos-er to R-22 than Forane® 427A in typical AC applications. A trade-off, however, is that R-407C is not formulated to work with MO/AB and requires POE oil. Also, the discharge pressures could be 15 to 25 psi higher than R-22., PRESSURE TEMPERATURE CHART HIGH ELEVATION 5,000 FEET Red Numerals - Inches Hg. Below 1 ATM Pressure (PSIG) High Elevation 5,000 feet Forane® Cylinder Identification 13/24/25 27/30 lb. (B) 50 lb. (C) 100 110 115/125 145 lb. (D) 100/200 650/690 lb. Drum (E) Container Style: Not to scale, FMI –2010 Energy & Store Development Conference HFC Component Comparison 1 –Relative to R-22, Standard Cycle @ 105 F Condenser, 25 F Evaporator, 10 F of Superheat & Subcooling 2 –From the IPCC AR4 3 –L Sub-classification Under Public Review Cond. Pressures (%) 1 V. R. Capacity (%) 1 COP (%) 1 Mass Flow Rate (%) 1 Discharge …, The human body is fascinating to study, which is why anatomy is such a popular subject. If you’re a student or the parent of a student – or if you’re just interested in studying anatomy, there are plenty of places where you can buy anatomy ..., Make your job easier with our handy refrigerant pressure temperature HVAC app with R-407C included., At temperatures above saturation, the refrigerant becomes super-heated vapor. At temperatures below saturation, refrigerant becomes sub-cooled liquid. Saturated refrigerant occurs in both evaporator and the condenser. A Refrigerant Temperature Pressure Reference Chart Shows Pressures at Various Temperatures for R22, R134A, R407C, R404A, R410A ... , R407c PT Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. 407a pt chart r22 suction pressure temperature chart r22 refrigerant pressure temperature calculator 407c superheat chart how to read a pt chart r407c refrigerant suction pressure discharge pressure r407c refrigerant ideal pressure 407c pt chart and bubble point, Refrigerants Temperature-Pressure Chart for R-22, R-410A, R-407C, R134A, R404A. Posted on 09/10/2022 11/11/2022 by Leo. Temperature: Refrigerant °F °C: R-22: R-410a: R-407c: R-134a: ... To find the exact value, you should consult the pressure-temperature (PT) chart specific to R404a. We currently have no such data in hand. …, PRESSURE-TEMPERATURE CHART at Sea Level TEMPERATURE °F REFRIGERANT - (Sporlan Code) 22 134a (V) (J) 5* -48 4* -47 3* -45 2* -44 1* -43 404A 407A 407C 407F …, AZ-50 (R-507A) Home / Products / Genetron ® AZ-50 (R-507A) Replacement for R-22 or R-502 and is the only azeotrope retrofit option suitable for flooded system conversions. Use for low and medium temperature refrigeration systems., Jun 9, 2022 · R-421A Refrigerant Facts & Info Sheet. June 9, 2022 by Brian Cole. R-421A is a highly efficient hydrofluorocarbon that is a drop-in replacement for R22 refrigerant. It consists of 2 components; that is, 58% of R-125 and 42% of R-134A. The refrigerant blend came into existence at a time when governments had signed a treaty to eliminate ozone ... , of 1 Refrigerant Guys PT – Chart R407C Refrigerant Gases Saturation Pressure-Temperature Data for R-407C (psig)* Temp. Pressure Temp. Temp. Pressure Temp. …, 145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart: